Call for pricing 408-850-1180
CABINET CONSTRUCTION:
• Stainless model has stainless steel front doors and sides on exterior. Interior is stainless steel side walls, back, floor, ceiling, and door liner. This unit includes LED interior lighting.
• Standard model (pictured at right with optional humidification and optional chart recorder) features stainless door, front, and brushed aluminum sides. Interior has aluminum side walls (looks like stainless steel), door liner,and back with stainless steel floor and ceiling.
DOORS:
• Positive seal, self-closing doors (gravity cam-lift) with 120 degree stay open feature. Door gasket removal and installation is tool-less. Glass door models feature double pane,"Low-E" glass.
INSULATION:
• Entire cabinet structure and doors insulated using foamed-in-place CFC free polyurethane foam.
SHELVING:
• Wire shelves (3 per door) available in stainless steel or PVC coated. Shelves capable of supporting up to 200 lbs. Gray PVC coated shelves are standard.
• Full height shelf support pilasters, with double oblong holes on 1" centers. Pilasters made of the same material as cabinet interior. Four (4) chrome plated, stainless steel shelf clips to be included for each shelf.
Standard Specs | |
Temperature Range | 20°C to 60°C |
Temperature Control | +0.2°C |
Temperature Uniformity | +0.7°C |
Ambient Temp. Recommendation | 21°+3°C |
Control Sensitivity | 0.1°C |
Control Readout | Actual and Set-Point Values |
Sensor | NIST-Traceable Platinum RTD |
Controller | Microprocessor based PID |
Calibration Capability | Yes, actual and set values |
Alarm | Audible and visible |
Alarm Type | Deviation in 0.1°C |
Remote Monitoring | Available |
Electrical | 115v, 60 Hz, 6 RLA |
Interior Cubic Feet | 49 net |
Required Clearance | 1" all sides |
Number of Shelves | 6 |
Cord Length | 7' |
Crated Weight | 780 lb |
REFRIGERATION SYSTEM:
• Top mounted, thermoelectric cooling system. Peltier based technology is solid state, highly efficient, reliable, and provides minimal vibration.
• Semi-Redundant cooling capability.
• Cooling surfaces act as dehumidifying modules at 25°C/60%RH and 30°C/65%RH
ELECTRICAL CHARACTERISTICS:
• Unit completely pre-wired at factory, and ready for final connection to a 115/60/1 phase - 15 amp dedicated (recommended) outlet. Unit runs approx. 6RLA under test conditions.• A cord and plug set is included.
• A sole use circuit is recommended.
Popular options include humidity control, glass door, chart recorder, timed lighting, and TraceLock electronic/audit capable locks.